Eagle Electronics 250i Fish Finder User Manual


 
60
3. Press to
DEEP ALARM ENABLED|ENT.
4. Press to
DEEP DEPTH and press ENT.
5. Use to change the first digit, then press to the next digit. Re-
peat these steps until the desired depth has been input. Press
ENT.
To switch to a different depth setting, open the Sonar Alarms menu and
repeat the instructions in steps 4 and 5 above.
Zone Alarm
The zone alarm is triggered when any echo passes inside the zone
alarm bar, shown on the right side of the screen.
To adjust and turn on the zone alarm:
1. Press MENU|MENU| to ALARMS|ENT| to SONAR ALARMS|ENT.
2. Press to
ZONE ALARM ENABLED| ENT| to ADJUST ZONE ALARM|ENT.
Sonar Alarms menu with Adjust Zone selected (left). Adjust Zone
Alarm selection box with Upper selected (right).
3. To set upper boundary for the Zone Alarm, use to select UPPER,
then press to move the top of the bar to the desired depth.
4. To set lower boundary for the Zone Alarm, use to select
LOWER,
then press to move the bottom of the bar to the desired depth.
5. Press
EXIT repeatedly.