Emerson 1500 Marine Instruments User Manual


 
OCT 2013 DANIEL™ SERIES 1500 TURBINE METER
SPECIFICATIONS2-2
INMETRO certification
Certification number
and marking
Applicable norms ABNT NBR IEC 60079-0:2008
ABNT NBR IEC 60079-1:2009
Temperature range -40/C # to # +60/C
Conditions for safe use (X) - The joint between the Universal Mounting Box cover and
housing is a flat joint and has a flame path of 9,52 mm in
length and clearance of less than 0,0381 mm.
- The joint between the Universal Mounting Box housing
and Sensor housing is a spigot joint which has a radial
length of 3,18 mm, an axial length of 13,61 mm and a
clearance of 0,059 mm.
- Device is to be remote-mounted when the process
temperature is outside of the ambient temperature range.
Ratings
The maximum working pressure for the Series 1500 Turbine Meter is based on the
temperature/pressure rating of the ANSI B16.5 flanges. The following chart lists the maximum
working pressure of both 304 stainless steel and carbon steel flanges at 100°, and 180°, and 400°
F. For maximum working pressures at intermediate temperatures, and for other materials, refer to
ANSI B 16.5.
Pressure/Temperature Carbon Steel Stainless Steel
150# ANSI / -20 to 100°F (-29° to 82°C)
285 psig WP 275 psig WP
150#ANSI / 180°F (82°C)
265 psig WP 239 psig WP
150#ANSI / 400°F (204°C)
200 psig WP 190 psig WP
300# ANSI / -20 to 100°F (-29° to 82°C)
740 psig WP 720 psig WP
300# ANSI / 180°F (82°C)
688 psig WP 624 psig WP
300# ANSI / 400°F (204°C)
635 psig WP 495 psig WP