Emerson 1500 Marine Instruments User Manual


 
DANIEL™ SERIES 1500 TURBINE METER OCT 2013
MAINTENANCE 5-1
5.0 MAINTENANCE
Reference Figures 7-1 through 7-6 Exploded Parts Drawings.
Item numbers reference actual engineering drawings and are not meant to be consecutively
numbered.
5.1 General
The Series 1500 Turbine is designed to operate for extended periods of time without evidence of
wear or loss of precision. All meter adjustments were completed at the factory during liquid
calibration and should not require field setup. However, should inspection of internal components
be required or should field requirements change, information contained in this document must be
read and understood before attempting any maintenance procedure.
If the Series 1500 Turbine is found to be in need of repair, it is recommended the user contact the
nearest Daniel Measurement and Control Sales or Service Office. It is important that servicing be
performed by trained and qualified service personnel.
5.2 Maintenance Considerations
1. Label all parts or place parts in labeled containers during disassembly.
2. Use no metal clamping devices in direct contact with any meter part or surface.
3. Rotor blades determine proper flow measurement and should be handled with extreme care.
Bending or altering the blades in any way can effect meter accuracy.