Furuno 2827W Marine RADAR User Manual


 
2. WIRING
2-12
2.3 Transceiver Unit
For FAR-2827W
Fabricating of RW-9600
1. Fabricate the RW-9600
cable as shown right.
2. Trim each wire (except
coaxial wire) considering its
location on the terminal
board.
4. Trim the shield leaving 30
mm and then fold back it.
5. Remove insulation of each
wire by about 6 mm.
6. Using the terminal opener,
insert each core (except
coaxial cable) to appropriate
connector plug.
7. Insert the coaxial cable to
the TB802 on TB Board and
fix the shield with cable
clamp.
Wiring for Coaxial cable
CAUTION
Clamp shied with bracket.
Tighten conductor with screw.
Procedures
1. Twist the conductor.
2. Press the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is ecure.
Terminal opener
Wiring for WAGO connector
WAGO connector
Wire
Twist
Press downward.
Do not use crimp-on lug to prevent
contact resistance from increasing.
Shield
Fold back shield.
Conductor
6
14
5
9
Coaxial cable
Approx. 250
5
30
Unit: mm
Vinyl sheath
Armor
Shield
Fold back the shield.