Furuno F A R Marine RADAR User Manual


 
2-2
6. Fold back armor by 5 mm and pass it through the two flat washers as shown in Figure 2-3.
Armor (folded back)
Gasket
Seal with putty
after tightening.
Vinyl sheath
Clamping gland
Flat
washer
Cable gland
Flat
washer
Flat
washer
Figure 2-3 Passing clamping gland, washers and gasket on the multicore cable
7. Shorten conductors considering their locations on the terminal board STB-1.
RTB-801
STB-1
Figure 2-4 Scanner unit, port side view
8. Confirm that armor is grounded between two flat washers.
9. Remove the sheath of each conductor by 6 mm. Fix crimp-on lugs (FV1.25-4, blue, ø4) to
each conductor. Make sure each connection is secure both electrically and mechanically.
10. Tighten the clamping gland.
11. Seal the cable gland with putty.
12. Connect the conductors to terminal board STB-1 referring to the interconnection diagram
on page S-1.