GE A166-0CG Marine GPS System User Manual


 
Restricted A166-0CG-1.00-2
Full
9
Appendix A:Messages Logged by the
Serial Status DCA
This appendix contains a description of all error messages posted to the WESMAINT Error Log
by the Serial Status DCA. This appendix also provides an explanation of all output return codes
returned by the Serial Status DCA.
During startup, the Serial Status DCA checks its configuration tables for invalid entries. If no
configuration errors are encountered the DCA attempts to spawn a number of processes during
start-up. If any invalid data is found or a problem is encountered while starting one of the
processes, an error message is logged to the WESMAINT Error Log.
Messages logged to the WESMAINT Error Log by the DCA will be pre-pended with a process
name. This name will be one of the following:
A166:
A166-<x>-<yy>: Where <x> is one of E, C or S
<yy> is a process number
Expressions in angular brackets like "<xx>", are filled with the appropriate values by the DCA.
A.1 Fatal Error Messages
Fatal error messages indicate the application is suspending due to either an invalid critical
configuration parameter, or a critical process initialization sequence failed.
F001: Unable to locate table <table_name>
Cause
The DCA was unable to locate one of its required configuration tables.
Remedy:
Ensure the <table_name> table exists and is comprised of at least one record.