GE A166-0CG Marine GPS System User Manual


 
GE Energy Services
Serial Status DCA
Configuration Guide
A166-0CG-1.00-2 Restricted
16
Full
I101:A166PORT rec <x>, Resp Timeout < <min>, defaulting
Cause
The Response Timeout configured in one of the port records is too small
Effect:
The Response Timeout in record <x> of A166PORT will default to a typical value (1000
character times).
Remedy:
·Refer to the chapter entitled Configuring the Port Table and ensure a valid Response
Timeout is configured in record <x> of A166PORT.
I102:A166PORT rec <x>, Char Timeout < <min>, defaulting
Cause
The Inter-Character Timeout configured in one of the port records is too small.
Effect:
The Inter-Character Timeout in record <x> of A166PORT will default to a typical value (5
character times).
Remedy:
Refer to the chapter entitled Configuring the Port Table and ensure a valid Inter- Character
Timeout is configured in record <x> of A166PORT.