GE A166-0CG Marine GPS System User Manual


 
Serial Status DCA
Configuration Guide
GE Energy Services
Restricted A166-0CG-1.00-2
Full
15
A.3 Warning Messages
Warning messages indicate recoverable run-time errors, either within the application or through
one of the software interfaces. The application will attempt to handle these errors without
suspending or jeopardizing the integrity of the system. If a warning message occurs repeatedly,
contact the Customer Service Department to report the error.
W001: Req_x failed, status = <x>
W002: Send_x failed, status = <x>
W003: WIN_read failed
W004: WIN_write failed
W005: <COMX> reset
W006: Reset Status DCA on <COMX>
W007: Rxed invalid resp: <Received Message in Hex format>
A.4 Information Messages
Information messages indicate the application is taking some special action based on certain
configuration or initialization criteria.
I001: No A166APPL table, deleting.
Cause
The DCA could not find the Main Application configuration table. If the Main Application
configuration cannot be located, the application assumes the user does not want it to run.
Effect:
The Serial Status DCA will delete itself from the system.
Remedy:
If the Serial Status DCA is intended to run, ensure the Main Application configuration table,
I100: A166PORT rec <x>, Flow Control <Flow Control Value>, disabling
Cause
One or more modem signals are enabled.
Effect:
Modem signals will default to disabled.
Remedy:
All modem signals must be disabled.