Intel SC5300 BRP Life Jacket User Manual


 
Setting Up the Chassis
36 Intel® Server Chassis SC5300 User Guide
Install Bezel Assembly (Pedestal Only)
NOTE
This step applies to a pedestal configured chassis only. For instructions on
installing a bezel in a rack configuration, refer to the Rack Conversion Kit
Installation Guide: Intel® Server Chassis SC5300.
TP00541
A
B
A
D
D
C
40
˚
Max
Figure 45. Installing Bezel Assembly
1. Open the Outer Bezel Door of the Bezel Assembly (letter “A”) and remove filler panels that
correspond to installed devices.
2. Close the Outer Bezel Door (letter “B”).
3. Fit the right edge of the Bezel Assembly against the right side of chassis and engage plastic
bezel hooks (letter “C”) into raised metal slots at chassis edge.
4. Rotate Bezel Assembly toward chassis and latch the two plastic tabs (letter “D”) on left side of
Bezel Assembly to chassis.