Invacare 1110532 SONAR User Manual


 
SECTION 9—DIAGNOSTIC CODES
Part No 1110532 35 MK
5
™NX™Electronics
4 E04 Right Motor Fault 00 Right Motor Short Circuit Check the right motor, connections and
motor cable.
01 Right Motor Open Circuit
02 Right Motor Connection Fault
B-
03 Motor Terminal Connected
to B+
04 Right Motor Voltage Fault
05 Right Motor Bridge Fault
06 Too Many Hardware Cur-
rent Limit Events
07 Current Offset Out of Range
08 Hardware Current Limit Fault
5 E05 Left Park Brake
Fault
00 Left Park Brake Drive-Time
Test Failed
Check the left park brake connections and
cable.
01 Left Park Brake Output
Enabled When Wheelchair
Idle
02 Left Park Brake Output Did
not Enable When Entering
Drive Mode
03 Left Park Brake fault during
power-up testing
04 Left park brake feedback low
during drive (park brake
short)
6 E06 Right Park Brake
Fault
00 Right Park Brake Drive-Time
Test Failed
Check the right park brake connections
and cable.
01 Right Park Brake Output
Enabled When Wheelchair
Idle
02 Right Park Brake Output Did
not Enable When Entering
Drive Mode
03 Right Park Brake fault during
power-up testing
04 Right park brake feedback
low during drive (park brake
short)
NUMBER OF FLASHES
DIAGNOSTICS CODE
ERROR CODE
DESCRIPTION
SUB CODE*
DETAILS OF
ERROR CODE
POSSIBLE