Lowrance electronic X-16 Marine GPS System User Manual


 
cable in
the event
a short
occurs.
Crimp
connectors
are
supplied
to
attach
the fuse
holder to the
power
cable. The red
wire in the
power
cable is the
positive
con-
ductor
The black wire
is the
ground
or
negative
conductor.
The
graph
is
protected
from
accidental
polarity
reversals and
no
damage
will occur if the wires
are reversed.
The unit will not
operate
until the
proper polarity
is
applied.
FIGURE 3
When
installing
the
power
cable,
you
will find two extra
wires com-
ing
from the
power
cable. The
green
one is for an
optional
Power
Booster and the other
white wire
is for connection to a Loran
C
receiver If neither of
these fea-
tures are
going
to be
used,
tape
the ends of the
green
and white
wires so that
they
cannot short
Refer to the Advanced
Operation
section for more information
on
these wires.
TRANSDUCER SELECTION
Lowrance offers
you
the choice
of transducers with
either an 8 or
20
degree
cone
angle
that will
interchange
with
any
of our 192
kHz sonar units. In other
words,
any
Lowrance
sonar instrument
can be used with
any
Lowrance
transducer of the same
frequency
without
retuning
of
any kind,
and
no loss of
performance. However,
the use of
any
other manufac-
turer's transducer will result in a
loss of
performance.
Now
you
can select the trans-
ducer
design
and cone
angle
to
best fit
your
specific
needs. Gen-
erally,
wide cone
angle
transdu-
cers
(20
degrees)
are
ideally
suited for
operating
in shallow
water or at medium
depths.
The
20
degree
cone
angle
allows
you
to see more of the underwater
world. In 15 feet of water the 20
degree
cone covers an area of
the
bottom thath about 6 feet across.
The 8
degree
transducer covers
only
about a 2 foot circle.
way
to slow the chart
paper
The
chart below
gives
the
range
of
the
Paper
Save function and the
amount that
each level slows
the
paper.
To
enable the
Paper
Save
function, simply press
the level of
paper
save
desired,
then
2nd,
then 6. The
paper
should slow
immediately.
For
example,
suppose you
wish to
slow the
paper
down to 1/4 its
present
speed.
Press 3
-
2nd
-
6 and the
paper
will now be
traveling
four
times slower than its
previous
speed.
When the
Paper
Save function
is
enabled,
the X-16 will
print
PSV=
and the level of
paper
save
that
you
selected. For
example,
in
our
previous
example
the
Paper
Save value was
3. The X-1 6 will
print
PSV=3 on the
bottom line of
the chart
paper (See
Figure 45.)
- --
1
Lao
34.0
-
- -
360
48,0
60.OFT— rL
LOUPAITCE PSU3
Figure
45
The
Paper
Save function can
also be used with the
Alternate
Transmit and Print function which
will cut
any Paper
Save
speed
in
half. This
gives
fourteen different
paper speeds
selectable
by
the
operator.
To disable the
Paper
Save
function,
simply press
0
-
2nd
-
6,
and the
paper
will
speed up.
PRINT INTENSITY
Three levels of
print intensity
are
provided
for different conditions.
The
stylus printing
can be
adjusted
to
print lighter
or darker
by using
the Print
Intensity
mode.
When the X-16 leaves the
factory,
the Print
Intensity
is set to level 1.
To
change
this
setting,
press
the
level of
intensity
desired,
from 0 to
2
(0
is
lightest,
2 is
darkest)
and
then
press
2nd
-
LINES.
For
example,
if the
stylus
is
printing
too
light, press
2
-
2nd
-
LINES and the
markings
on the
chart
paper
should become
darker
This feature is useful when a
stylus
becomes old.
By
using
the
'2" level or darkest
level,
the
printing
can
improve. If,
when
using very
slow
paper speeds,
the
record has much
overprint
due to
multiple stylus
strikes in a small
area,
the '0" or
lightest
level can
PAPER SAVE
LEVEL CHART SPEED REDUCED
TO
1
1/2
2
1/
3
1/4
4
1/5
5
1/6
6
1/
7
1/
FIGURE 4
Co,e
AnSI.
I
O.pth
L.
7ft
lIlt I
II" 4
I
III' 11 13
1240 28 7' I
50'
100'
150'
200'
8°at3db
4
25
PDF compression, OCR, web-optimization with CVISION's PdfCompressor