Mustang Survival md2010 Life Jacket User Manual


 
12
portion of the PFD in accordance with the CARE AND
MAINTENANCE INSTRUCTIONS (p. 12).
CARE AND MAINTENANCE
INSTRUCTIONS
Check the following at the intervals listed below.
1. Each Use: Remove and inspect the CO2 cylinder from
the inflator. For the MD2012 – Also remove the clear
auto cap and bobbin from the inflator.
i. Check all components for dirt or corrosion.
Clean or replace.
ii. Check that the CO2 cylinder has not been
pierced. Replace with Inflatable PFD 20 gram
CO2 cylinder if necessary. The cylinder for the
MD2010 is contained in accessory pack MA2010.
The cylinder for the MD2012 is contained in
accessory pack MA2012.
iii. If your PFD has a metal lever attached to the
pull tab, check the lever to ensure it is in the up
and ready position with the green indicator pin
properly installed.
iv. If your PFD has a red lever attached to the pull
tab, check the lever to ensure it is retracted with
the green indicator clip properly installed.
2. Every Three (3) Months: Leak Test the Inflatable PFD
every three months.
i. Orally inflate your Inflatable PFD until firm and
let stand overnight. A leaking Inflatable PFD will
not hold its firmness and should be replaced.
If your Inflatable PFD leaks, take it to your
Mustang dealer for evaluation and/or servicing.
Repack the Inflatable PFD as outlined in the
Repacking section (p. 11).
3. Annually:
i. To check the oral inflation valve, fully inflate PFD
and hold valve under water. If bubbles appear,
deflate and reinflate to test again. Should the
leak persist, take your Inflatable PFD to your
dealer for proper servicing.