Mustang Survival MD3091 Life Jacket User Manual


 
1. Tie the conversion cap lanyard through the
eyelet located within the front slash entry
(Figure 39). Allow enough length such that
the manual cap can be stowed in the interior
pocket located below the inflator inside the
slash entry (Figure 39).
2. Position the conversion cap over the hydrostatic
water inlet valve (Figure 40).
3. Secure the conversion
cap to the hydrostatic
water inlet by
applying pressure to
the cap at the metal
clip until it locks in
place (Figure 41).
Reversing the Conversion
1. To remove the conversion cap, open the front slash
entry.
2. Reach above the inflator to find the conversion cap
lanyard. Follow the lanyard to the conversion cap.
3. Push the fabric of the slash entry behind the water
inlet valve (Figure 42).
4. Firmly pull the conversion cap lanyard horizontally
across the chest.
5. Place the conversion cap in the manual conversion
cap pocket located inside the front slash entry
when not in use.
6. Visually confirm the conversion cap has been removed from the valve
opening.
CARE AND MAINTENANCE
Before each use, review the Readiness Checklist.
CAUTION: After each inflation, re-arm the LP – see Re-arming.
After each use, deflate, re-arm, and repack the LP – see:
• Deflating
• Re-arming
• Repacking
Visually inspect the LP prior to use to ensure:
• LP is properly armed
FiGURE 39
FiGURE 40
FiGURE 41
FiGURE 42
Compact Tactical LP Owners Manual
13