Nautique 216 Boat User Manual


 
4-76
Section 4
To drain: Press and hold the button until the LED begins to flash
and the pump will begin to drain the tank. Press the button again
to stop the pump.
The pump will stop pumping when the tank sensor senses the “No
Water Level” in the tank. The LED will continue to flash for
approximately 10 minutes unless the button is pressed again.
Automatic Bilge Panel (standard with keyless ignition)
Bilge Pump Only Mode - This feature is activated by a switch located
on the side console. The switch has three positions, ON, OFF and
BILGE. If the boat is going to sit for more than a few days with the
bilge pumps on, it is important the switch is set in the BILGE
position to minimize battery drain. This will activate the bilge pump
and shut off power to the Serial Switching and Keyless Ignition
System. It is important to remember the engine or other accessories
can not be used unless the switch is in the ON position.
An indicator light is located with the switch for the bilge pump. The
indicator light will come on anytime the bilge pump is activated. If
your panel has a circuit breaker, the circuit breaker is only active
when the switch is in the BILGE position.
Bilge Pump On
All Off
All On
Bilge
Bilge
Pump
Pump
Circuit
Breaker
Indicator
CORC024
CORC0273