79
Fig.88-DV2MAIN
DV 1 (DELAYED VIOLATION 1)
If you remain shallower than a Deco Stop Depth for more than
5 minutes, operation will enter DV1* which is a continuation of
CV with penalty time still being added. Again, the audible will
sound and the full TLBG will flash (Fig. 87) until it is silenced.
*The difference is that 5 minutes after surfacing from the dive,
operation will now enter Violation Gauge Mode.
• S (< 2 sec) - to silence audible.
> Down Arrow icon continues to flash until descent to below
required Stop Depth, then full Stop icon will be on solid.
DV 2 (DELAYED VIOLATION 2)
If the calculated Deco obligation requires a Stop Depth between
60 FT (18 M) and 70 FT (21 M), operation will enter DV2.
The Audible will sound and the alarm LED will flash. The full
TLBG will flash (Fig. 88) until the audible is silenced.
• S (< 2 sec) - to silence audible.
> Up Arrow icon flashes if 10 FT (3 M) deeper than the
required Stop Depth.
> Once within 10 FT (3 M) of and below the required Stop
Depth, the Stop icon (both Arrows with Stop Bar) will be
displayed solid.
Fig.87-DV1MAIN
(duringAudible)