NOTE: When the data rate is set to 2.048Mb/s, then the unit is
forced into G.703 mode, and it transmits user data on all 32 times-
lots. There is no framing information; therefore, the CAS MF
(SW2) switch is ignored. SW3 is defaulted to clock mode. In all
other rate settings, the unit employs G.704 framing; TS0 is
reserved for signaling.
3.2 SOFTWARE CONFIGURATION
The Model 2094 features a menu-driven command system that
allows you to monitor/configure its operating parameters. Follow the
instructions below to configure the Model 2094 using the software
switches:
1) Plug the 9-pin male end of the cable to your terminal or com-
puter’s DB-9 serial port and start up the terminal emulator
software if necessary. Plug the miniature stereo plug into the
rear of the unit. The small recessed jack on the right side of
the unit is the control port jack.
NOTE: If your terminal uses a DB-25 connector, please use
a DB-9 to DB-25 Adapter to connect to the cable (See Model
18PC-M).
2) Power up the terminal and set its RS-232 port as follows:
9600 Baud
8 data bits, 1 stop bit, no parity
Local echo off
ANSI or VT-100 emulation
Xon/Xoff software flow control enabled
3) Here is an example of a terminal emulator setup session. In
normal font are the various parameter types. In bold type are
the values that should be used for best results. Your terminal
program’s setup screen may differ from this one:
11
4) When the unit is first turned on, the terminal screen may
appear blank. Press the [Enter] key. If your serial connection
is good, then the unit will immediately display a password
prompt. The following message will appear in the middle of
the screen:
5) Type in the password and press [Enter]. The factory default
password for the unit is:
patton
NOTE: The password is case sensitive. If the entry is incor-
rect, the password screen will clear and prompt you again for
the correct password. The password you enter will not be
shown. For security, asterisks will be displayed for each letter
you type. The maximum length of the password, which can
include any character the terminal can generate, is 16 charac-
ters.
6) The Model 2094 will then display the Main Menu screen.
12
Baud rate: 9600 Parity: None Data Length: 8 Stop Bits: 1
Default terminal type: VT100
Local Echo: Off
Add Line Feeds after CRs: Off
Received Backspace Destructive: On
Backspace key sends: BS
XON/XOFF software flow control: On
CTS/RTS hardware flow control: Off
DSR/DTR hardware flow control: Off
Patton Electronics
Menu Management
Enter Password: _