Q-Logic 2-Gb Fibre Channel to PCI-X Host Bust Adapter Marine RADAR User Manual


 
7 Windows XP Driver Installation
System Registry Parameters
FC2354601-00 A 7-7
4. If the string FCTape= does not display, add the following text to the end of
the string:
;FCTape=1
5. If the string FCTape=0 displays, change the value from 0 to 1.
6. Click OK.
7. Exit the REGEDT32 program, then restart the system.
7.5.4
UseSameNN
If you have multiple QLA23xx HBAs on the same system, the driver assigns the
world wide node name obtained from the first HBA to the rest of the HBAs.
If you want to have the world wide node name for each HBA to be based on its own
NVRAM content, set the UseSameNN parameter to 0.
Follow these steps to change the UseSameNN parameter:
1. Click Start, select Run, and open the REGEDT32 program.
2. Select HKEY_LOCAL_MACHINE and follow the tree structure to the
QL2300.SYS driver:
HKEY_LOCAL_MACHINE
SYSTEM
CurrentControlSet
Services
Ql2300
Parameters
Device
3. Double-click DriverParameters:REG_SZ:MSCS=2;UseSameNN=1.
4. If the string UseSameNN= does not display, add the following text to the
end of the string:
;UseSameNN=0
5. If the string UseSameNN=1 displays, change the value from 1 to 0.
6. Click OK.
7. Exit the REGEDT32 program, then restart the system.