3
PRE-OPERATION INSTRUCTIONS
1
1.1.3 Specifications
(1) Output signals
Voltage output (across terminals AM0-AMC) 0 to 10VMAXDC
Current output (across terminals AM1-AMC) 0 to 20mADC
(2) Output resolution
Voltage output 3mV
Current output 10
µA
(3) Output accuracy (reference value)
±10% of the full-scale output value
Depends on the output signal type.
(4) Meters used
• Voltmeter
DC voltmeter Full-scale 10V (internal impedance 10kΩ or more)
• Ammeter
DC ammeter Full-scale 20mA (internal impedance 300Ω or less)
• Wiring length
Maximum 10m