Simrad AP26 Marine Instruments User Manual


 
Installation
20221586B 67
RATE
COMPASS
AP16, AP25, AP26
Figure 3-13 RC36 connection to autopilot control unit
Plug the RC36 into a Robnet2 connector (see Figure 3-9) or cut
the connector from the cable and connect the wires in parallel
with the cable shown in Figure 3-11.
3.14 RFC35 Fluxgate Compass installation
(Optional back-up)
The RFC35 Fluxgate Compass is a magnetic sensor, which
means you have to take the same precautions at installation as
for the standard RC36 (see previous page).
Connect the RFC35 to the autopilot computer as per Figure
3-14.
RFC35
FLUXGATE
COMPASS
AUTOPILOT COMPUTER
MAIN PCB
Heading
Sensor
*
* NON POLARIZED
(COLOR INDEPENDENT)
HS+
HS-
Figure 3-14 RFC35 connection