Simrad RGC12 Boating Equipment User Manual


 
Robertson RGC12 Gyro Compass
20220737B
14
5. The safe distance for magnetic compass is clearly shown
on each unit. Install units in accordance with these safe
distances.
6. Be sure to install the recommended cables separated
according to the function of each cable, as shown by
separate cable list or inter unit wiring diagram (see Figure
4-5, page 21).
7. Be sure to install all the equipment cable more than 5 m
away from radio equipment feeders if possible.
8. Connect terminals marked with
to the ground
terminals of the ship. Shield end of shield cable is to be
finished close to the terminal board and connect to the
ground terminals of the ship.
9. Armour of cable end for the master compass should be
finished 20~30 mm before the cable entrance for easy
connecting to terminals.
10. Since semiconductor elements are used in the equipment.
do not use a megger for any test.
11. Any shipyard that installs this equipment for the first
time should be given instructions by Simrad or
Kongsberg Simrad service engineers.