Topcon GPT-2006 Marine Instruments User Manual


 
4-12
4 DISTANCE MEASUREMENT
6 Measure the second and third points in the same
way.
Collimate
P2
[F1]
Collimate
P3
[F1]
The instrument calculates and displays coordinate
and distance value of cross point between
collimation axis and of the plane. *1),2)
7 Collimate the edge (P0) of the plane. *3) ,4)
Collimate
P0
8 To show the slope distance (SD), press the [ ]
key.
Each time pressing the [ ] key, horizontal
distance, relative elevation and slope distance are
shown in sequence.
To show coordinate of point P0, press the [ ]
key.
9 To escape the measuring, press the [F1](EXIT)
key. The display returns to the previous mode.
*1) In case the calculation of plane was not successful by the measured three points, error displays. Start
measuring over again from the rst point.
*2) Data display is the mode beforehand of offset measurement mode.
*3) Error will be displayed when collimated to the direction which does not cross with the determined plane.
*4) The point height of the target point P0 is set to zero automatically
PLANE
N002#:
N
P
SD: m
MEAS --- NP/P ---
PLANE
N003#:
N
P
SD: m
MEAS --- NP/P ---
HR: 80°30'40"
HD: 54.321 m
N
P
VD: 10.000 m
EXIT
HR: 75°30'40"
HD: 54.600 m
N
P
VD: -0.487 m
EXIT
V : 90°30'40"
HR: 75°30'40"
N
P
SD: 56.602 m
EXIT