Topcon GPT-2006 Marine Instruments User Manual


 
7 DATA COLLECTION
7-19
7.6 Setting Parameter of Data Collect [CONFIG.]
In this mode, the following settings of data collect mode are possible.
Setting Items
How to Set Items
Example Setting: DATA CONFIRM : YES
Menu Selecting Item Contents
F1:DIST MODE
FINE / CRS(1) /
CRS(10)
Select Fine /Coarse(1) /Coarse(10) mode in distance
measurement mode.
The unit to be displayed is as follows.
Fine mode: 1mm (0.2mm)
Coarse (1) mode: 1mm
Coarse (10) mode: 10mm
F2:HD/SD HD/SD
Select the distance measurement mode Horizontal
Distance or Slope distance.
F3:MEAS. SEQ.
N-TIMES /
SINGLE / REPEAT
Select to set measurement mode for distance
measurement.
F1:DATA CONFIRM YES/NO
It is possible to conrm the result of measuring data
before the data is recorded.
F2:COLLECT SEQ.
[EDIT
MEAS] /
[MEAS
EDIT]
Select the procedure of data collection.
[EDIT
MEAS] :Measurement is carried out after
entering other data.
[MEAS
EDIT] :Measurement is carried out before
entering other data.
F3:NEZ AUTO. CALC ON/OFF
It is possible to calculate coordinate value of data collected
and store it into coordinate data le in every data collection.
Operating procedure Operation Display
1 Press the [F3] (CONFIG.) key from the data collect
menu 2/2.
The CONFIG menu 1/2 is shown.
[F3]
2 Press the [F4](P
) key to display the CONFIG
menu 2/2.
[F4]
3 Press the [F1] (DATA CONFIRM) key.
[ ] indicates the current setting.
[F1]
4 Press the [F1] (YES) key.
[F1]
5 Press the [F4] (ENTER) key.
[F4]
DATA COLLECT 2/2
F1:SELECT A FILE
F2:PCODE INPUT
F3:CONFIG. P
CONFIG. 1/2
F1:DIST MODE
F2:HD/SD
F3:MEAS. SEQ. P
CONFIG. 2/2
F1:DATA CONFIRM
F2:COLLECT SEQ.
F3:NEZ AUTO. CALC P
DATA CONFIRM
F1:YES
[F2:NO ]
ENTER
DATA CONFIRM
[F1:YES]
F2:NO
ENTER