Toshiba Three-phase 200V class 0.1 to 2.2kW Marine Battery User Manual


 
E6581090
K-4
11
  Frequency parameters
Title
Communication
No.
Function Unit
Minimum setting
unit Panel/
Communication
Adjustment range
Default
setting
User
setting
Reference
H 0201 VI/S3 reference point 1
setting
%1/10-100 0 6.4.1
H 0202 VI/S3 point 1
frequency
Hz 0.1/0.01 0-200 0.0 6.4.1
H 0203 VI/S3 reference point 2
setting
%1/10-100 100 6.4.1
H 0204 VI/S3 point 2
frequency
Hz 0.1/0.01 0-200 *2 6.4.1
H 0240 Starting frequency
setting
Hz 0.1/0.01 0.5-10.0 0.5 6.5.1
H 0241 Operation starting
frequency
Hz 0.1/0.01 0.0-HJ 0.0 6.5.2
H 0242 Operation starting
frequency hysteresis
Hz 0.1/0.01 0.0-HJ 0.0 6.5.2
H 0250 DC braking starting
frequency
Hz 0.1/0.01 0.0-HJ 0.0 6.6.1
H 0251 DC braking current % 1/1 0-100 50 6.6.1
H
0252 DC braking time S 0.1/0.1 0.0-20.0 1.0 6.6.1
H 0270 Jump frequency Hz 0.1/0.01 NN-WN 0.0 6.7
H
0271 Jumping width Hz 0.1/0.01 0.0-30.0 0.0 6.7
H 0287 Preset speed operation
frequencies 8
Hz 0.1/0.01 NN-WN 0.0
H 0288 Preset speed operation
frequencies 9
Hz 0.1/0.01 NN-WN 0.0
H 0289 Preset speed operation
frequencies 10
Hz 0.1/0.01 NN-WN 0.0
H 0290 Preset speed operation
frequencies 11
Hz 0.1/0.01 NN-WN 0.0
H 0291 Preset speed operation
frequencies 12
Hz 0.1/0.01 NN-WN 0.0
H 0292 Preset speed operation
frequencies 13
Hz 0.1/0.01 NN-WN 0.0
H 0293 Preset speed operation
frequencies 14
Hz 0.1/0.01 NN-WN 0.0
H
0294 Preset speed operation
frequencies 15
Hz 0.1/0.01 NN-WN 0.0
5.11
*2:The value is changed according to the set-up parameter condition.
(VFNC1 (S)-□□□□P-W type)
FH:80, UL80, VL:60, F127:0, F170:60, F171:200, F204:80, F409:200, F417:1710 for VFNC1 (S)-□□□
PL- type.