• Do not install in any location of high
temperature, high humidity, moisture
condensation and freezing and avoid
locations where there is exposure to water
and/or where there may be large amounts
of dust, metallic fragments and oilmist.
• Do not install in any location where
corrosive gases or grinding fluids are
present.
• Operate in areas where ambient temperature ranges from -10°C to 50°C. However, when
installing the inverter where the ambient temperature will rise above 40°C, detach the caution
label on the top surface.
5cm
5cm
5cm
Measurement
position
Measurement
position
Note: The inverter is a heat-emitting body. Make sure to provide proper space and ventilation
when installing in the cabinet. When installing the inverter in a cabinet, you are
recommended to detach the caution label even if the temperature in the cabinet is below
40°C.
• Do not install in any location that is subject to large amounts of vibration.
• If the VF-nC1 Inverter is installed near any of the equipment listed below, provide measures to
insure against errors in operation.
Solenoids: Attach surge suppressor on coil.
Brakes: Attach surge suppressor on coil.
Magnetic contactors:Attach surge suppressor on coil.
Fluorescent lights: Attach surge suppressor on coil.
Resistors: Place far away from VF-nC1
Inverter.
Resistor