Toshiba Three-phase 200V class 0.1 to 2.2kW Marine Battery User Manual


 
E6581090
E-5
5
5.4 Selecting forward and reverse runs (operation panel only)
HT 
: Forward/reverse selection (Operation panel)
[Parameter setting]
Title Function Adjustment range Default setting
HT
Forward/reverse selection
(Operation panel)
0: Forward run
1: Reverse run
0
Check the direction of rotation on the status monitor.
HTH : Forward run   HTT : Reverse run ⇒ For monitoring,
see 8.1.
When the F and R terminals are used for switching between forward and reverse
rotation from the terminal board, the HT forward/reverse run selection is rendered
invalid.
Short across the F-CC terminals: forward rotation
Short across the R-CC terminals: reverse rotation
This function is valid only when EOQF is set to K (operation panel).
5.5 Setting acceleration/deceleration time
CEE
: Acceleration time 1 (s)
FGE
: Deceleration time 1 (s)
Set acceleration time from 0Hz operation frequency to maximum frequency HJ and deceleration
time as the time when operation frequency goes from maximum frequency HJ to 0Hz.
O
utput frequency (Hz)
FGE
CEE
HJ
Time (s)
0
[Parameter setting]
Title Function Adjustment range Default setting
CEE
Acceleration time 1 (s) 0.1-3000 seconds 10.0
FGE
Deceleration time 1 (s) 0.1-3000 seconds 10.0
If the programmed value is shorter than the optimum acceleration/deceleration time determined
by load conditions, overcurrent stall or overvoltage stall function may make the
acceleration/deceleration time longer than the programmed time. If an even shorter
acceleration/deceleration time is programmed, there may be an overcurrent trip or overvoltage
trip for inverter protection. (For further details, see 13.1).
Function
1) For acceleration time CEE, program the time that it takes for the inverter output
frequency to go from 0Hz to maximum frequency HJ.
2) For deceleration time FGE, program the time that it takes for the inverter output
frequency to go from maximum frequency HJ to 0Hz.
Function
Program the direction of rotation when the running and stopping are made using the RUN
key and STOP key on the operation panel. Valid when EOQF (command mode) is set to
1 (operation panel).