Xantrex Technology Freedom SW 2000 Marine Battery User Manual


 
24 Freedom SW 2000 Installation Guide
Installing the Inverter/Charger
Step 4: Connecting the DC Cables
DC Connection Precautions
Recommended Cable Sizes and Lengths and Fuse Size
For recommended DC cables and fuse size, see Table 3 on page 11.
Preparing the Cables
To prepare the DC cables:
1. Cut the negative and positive cables to the required length. Strip off
enough insulation so you can install the terminals you will be using.
Xantrex recommends the use of crimp connectors. The connector
should be designed for a 5/16" DC stud size on the Freedom SW 2000
inverter, while battery/fuse cable end may require a larger size such as
3/8" to connect to the Freedom SW 2000. If a crimp connector is used,
it should be crimped using the tool indicated by the connector
manufacturer.
2. Cut the DC ground cable to the required length. Strip off enough
insulation so you can install the terminals you will be using.
Xantrex recommends the use of crimp connectors. The connector
should be designed for a 1/4" stud size to connect to the Freedom SW
2000. If a crimp connector is used, it should be crimped using the tool
indicated by the connector manufacturer.
3. Attach the connectors to the ends of both cables. Make sure no stray
wire strands protrude from the connectors.
ELECTRICAL SHOCK HAZARD
Connect and disconnect DC wiring only after opening the disconnect
switches or breakers at all AC and DC sources.
Failure to follow these instructions will result in death or serious
injury.