34 Freedom SW 2000 Installation Guide
Installing the Inverter/Charger
Step 7: Testing Your Installation
There are several tests to be performed for testing your installation. These
tests will verify that:
• the Freedom SW 2000 works in invert mode,
• the Freedom SW 2000 works in charge mode, and
• the Freedom SW 2000 works in AC pass-through mode.
If the test fails at any point, go to “Step 6: Performing Checks Prior to
Initial Start-Up” on page 33 and go through the checklist again to check the
installation. Then perform the test again. If the test fails again, see the
troubleshooting section in the Freedom SW 2000 Sine Wave Inverter/
Charger Owner’s Guide.
Testing in Invert Mode
To test the Freedom SW 2000 in invert mode, using a 100 watt light
bulb as the test load:
1. Close the DC disconnect switch or the DC circuit breaker to supply
DC power to the Freedom SW 2000.
Make sure the voltage at the DC terminals on the Freedom SW 2000 is
correct, as described in “Step 6: Performing Checks Prior to Initial
Start-Up” on page 33.
2. Apply DC power to the inverter by switching on the DC disconnect
circuit breaker and then pressing the ON/STANDBY switch once.
The inverter will go through a self-test.
• Each of the indicator lights will flash in sequence,
ELECTRICAL SHOCK HAZARD
The Inverter Enable button on the Freedom SW 2000 and the optional
accessories do not disconnect DC or AC input power to the Freedom SW
2000.
Failure to follow these instructions can result in death or serious
injury.
Figure 10
Freedom SW 2000 Front Panel
FREEDOM
SW
2000
1000
800
600
400
30
100
200
Max Off
Low Battery Battery Type Search Battery Bank
Cutoff Mode Capacity (Ah)
AGM/
LOW HIGH GEL Flooded
W
Inverting
A
Charging