Xantrex Technology HW 1000 Marine Battery User Manual


 
3–4 975-0467-01-01
To cycle through the various feature settings:
1. Press and hold the Power button for five seconds to enter the feature
settings mode.
2. Press the Power button to toggle between the following information:
To change the charger’s charging current setting:
By default the
charging current
is set to 55 A.
1. Press and hold the Power button for five seconds.
The LED screen will flash “Cur” intermittently.
2. Press the Select button once.
The LED screen will display the present charging current setting.
Example, “55A” for a 55 A setting.
3. Press the Select button again to change to the next setting.
The LED screen shows the next setting. Example, “5A” for a 5 A
setting.
4. Continue pressing the Select button to cycle through each of the four
settings – “5A”, “15A”, “35A”, and “55A” until you reach the desired
setting.
5. Press and hold the Select button for five seconds to make the setting
permanent.
Setting LED Screen
Charging Current
Setting
Cur
Inverter Mode Setting IN
Alarm Setting aL
Shutdown Setting sd
Factory Setting def