4–14 975-0467-01-01
Table 4-3 below illustrates the battery charging voltage and current
settings.
Routine Maintenance
Freedom HW Unit
Minimal maintenance is required to keep your Freedom HW operating
properly. Periodically you should:
• Clean the exterior of the unit with a damp cloth to prevent the
accumulation of dust and dirt.
• Ensure that the DC cables are secure and fasteners are tight.
• Make sure the ventilation openings are not clogged.
Batteries
When possible, you should recharge your batteries whenever a low
voltage warning or a shutdown occurs with the Freedom HW. This gives
the batteries a much longer life than recharging when the batteries have
been almost completely discharged.
Table 4-3
Battery Charging Voltage and Current Settings
Battery Type Bulk/Absorption
Voltage (Volts)
Float Voltage
(Volts)
Charge Current
(Amps)
Float Current
(Amps)
Flooded 14.4 13.5 5, 15
35, 55
1.5
4.5
GEL 14.2 13.8 5, 15
35, 55
1.5
4.5
AGM 14.3 13.4 5, 15
35, 55
1.5
4.5
Fixed 13.5 13.5 5, 15, 35, 55 not applicable