Xantrex Technology HW 1000 Marine Battery User Manual


 
Battery Charging
975-0467-01-01 4–13
Table 4-2
Battery Charging Status LED
Status LED Display Screen Condition
Solid GREEN
FUL
Battery is FULL.
Flashing
GREEN
BULCHg
12.8
(where 12.8 is an
example of battery
voltage)
Battery is in BULK CHARGE.
ABSCHg
14.2
(where 14.2 is an
example of battery
voltage)
Battery is in ABSORPTION CHARGE.
Solid RED
E10 to e12
See Table 5-1, “Error Codes Displayed on the Display Panel
Screen” on page 5–5.
Solid GREEN
or
Flashing
GREEN
5A or 15A or 35A
or 55A
Select button is pressed to display present Charging Current
setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.
IN0 or In1
Select button is pressed to display present Inverter Mode
setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.
aL0 or AL1
Select button is pressed to display present Alarm setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.
sdL or sdH
Select button is pressed to display present Shutdown setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.