Electrical Specifications: Charge Mode
975-0467-01-01 A–3
Electrical Specifications: Charge Mode
AC Input
Operating voltage range 95–135 Vac
Nominal current 12Aac at 55A charge, 120 Vac in
Nominal frequency 60 Hz
DC Output
Nominal voltage 12.0 Vdc
Min battery voltage for charging 0.0 Vdc
Max output voltage 14.4 Vdc
Nominal output current User selectable:
5 A, 15 A, 35 A, 55 A
Charger current derating Automatically reduce charger
current as internal temperature
exceeds 80 °C, and input Vac
approaches low transfer.
Efficiency at nominal output ≥78%
Other
Battery type settings Flooded (default), Gel, AGM, or
Fixed (13.5V)
Charge algorithms Three stages (Bulk, Absorption,
and Float)
Independent battery banks 1