Xantrex Technology HW 1000 Marine Battery User Manual


 
4–6 975-0467-01-01
Status LED During Inverter Mode
The following summarizes the behavior of the Status LED during Inverter
mode.
Table 4-1
Status LED during Inverter Mode
Status LED Display Screen Condition
Solid
YELLOW
12.8
(where 12.8 is an
example of battery
voltage)
Select button is pressed to display Input Battery Voltage.
The Input Battery Voltage LED lights up.
Value in display screen is shown as Volts.
11
(where 11 is an
example of current)
Select button is pressed to display Input Current.
The Input Current LED lights up.
Value in display screen is shown as Amps.
0.85
(where 0.85 is an
example of output
power in Kilowatts)
Select button is pressed to display Output Power.
The Output Power LED lights up.
Value in display screen is shown as Kilowatts.
5A or 15A or 35A
or 55A
Select button is pressed to display present Charging Current
setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.
IN0 or In1
Select button is pressed to display present Inverter Mode
setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.
aL0 or AL1
Select button is pressed to display present Alarm setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.
sdL or sdH
Select button is pressed to display present Shutdown setting.
None of the info and setting LED lights are on.
Present setting is displayed on the screen.
E05 through e07
Warning condition detected while AC output power is still
available.
See Table 5-1, “Error Codes Displayed on the Display Panel
Screen” on page 5–5.