Baldor MIN1853 Outboard Motor User Manual


 
Setup 5-13MN1853
Configure End of Travel Switch Polarity
Configuring Motor Type [ ET ]
EDIT
> SETUP > I/O > LIMITS
Value: NORM CLOSED
Range: NORM OPEN or NORM CLOSED
Axis One EOT POL
←↑ NORM CLOSED ↓→
Allows selection of Normally Open or Normally Closed polarity of the
End of Travel switch (EOT). Use ↑↓ to select the definition.
Select value, press ENTER
Configure JOG Parameters
The keypad provides a convenient way to jog the motor. The parameters that
control your jog operation are configured using the JOG SETUP menu:
Action
Display Comments
Press F2 (JOG) for more sub
menu selections.
SETUP
I/O JOG HOME
Select a submenu, press F1 (I/O), F2
(JOG), or F3 (HOME).
Press key for more sub menu
selections.
JOG SETUP
ACCEL LOVEL HIVEL
Select a submenu, press F1 (ACCEL),
F2 (LOVEL), or F3 (HIVEL).
JOG SETUP
ENABLE
Select a submenu, press F1
(ENABLE)
Configuring JOG Acceleration [ JAr ]
EDIT
> SETUP > JOG > ACCEL
Value: 0.1 {Accel Units}
Range: 0.09999999.0
Axis One JOG Accel
0.1 sec
Sets the acceleration and deceleration used during a jog move. Use
the numeric keys to enter a value (units were selected in the SETUP
> MECH > ACCEL menu).
Select value, press ENTER
Configuring JOG Low Velocity [ JLr ]
EDIT
> SETUP > JOG > LOVEL
Value: 0.1 {Velocity Units}
Range: 0.09999999.0
Axis One JOG LoVel
0.1 in/s
Sets the low speed JOG velocity. Use the numeric keys to enter a
value (units were selected in the SETUP > MECH > VEL menu).
Select value, press ENTER