Baldor MIN1853 Outboard Motor User Manual


 
5-14 Setup MN1853
Configuring JOG Low Velocity [ JHr ]
EDIT
> SETUP > JOG > HIVEL
Value: 5.0 {Velocity Units}
Range: 0.09999999.0
Axis One JOG HiVel
5.0 in/s
Sets the high speed JOG velocity. Use the numeric keys to enter a
value (units were selected in the SETUP > MECH > VEL menu).
Select value, press ENTER
Configuring JOG Enable [ JEi ]
EDIT
> SETUP > JOG > ENABLE
Value: Enabled
Range: Disabled or Enabled
Axis One JOG Enable
Enabled
Enables or disables JOG features. When disabled, an error
message is displayed when the jog buttons are pressed. JOG is
often disabled after installation to prevent access.
Select value, press ENTER
Configure HOME Parameters
The homing function combines the flexibility of a customized homing routine with
the ease of use of calling a canned program. (Also see the GH command).
Action
Display Comments
Press F3 (HOME) for more sub
menu selections.
SETUP
I/O JOG HOME
Select a submenu, press F1 (I/O), F2
(JOG), or F3 (HOME).
Press key for more sub menu
selections.
HOME SETUP
MODE EDGE SWITCH
Select a submenu, press F1 (MODE),
F2 (EDGE), or F3 (SWITCH).
Press key for more sub menu
selections.
HOME SETUP
OFFSET DIR
Select a submenu, press F1
(OFFSET) or F2 (DIR).
Configuring Homing Mode [ HMi ]
EDIT
> SETUP > HOME > MODE
Value: Switch Only
Range: Switch Only
Axis One Home Mode
←↑ Switch Only ↓→
Sets how a Go Home (GH) command will execute. The control will
only search for the appropriate edge of a switch.
Only one selection available.