Fluke 199 Marine Radio User Manual


 
Specifications
10:1 Probe
9
101
Figure 52. Safe Handling: Max. Input Voltage Between
Scope References, and Between
Scope References and Meter Reference
10:1 Probe
Safety
Max. Input Voltage ..........................1000 V CAT II
600 V CAT III
Max. Floating Voltage
from any terminal to ground...................1000 V CAT II
600 V CAT III
up to 400 Hz
Electrical specifications
Input Impedance at probe tip10 M (±2 %)//14 pF (±2
pF)
Capacity Adjustment Range .........................10 to 22 pF
Attenuation at DC (1 M
input) ....................10 x (±2 %)
Bandwidth (with FLUKE 199)...... DC to 200 MHz (-3 dB)
Environmental
Temperature
Operating ...........................0 to 50
°C (32 to 122 °F)
Storage........................ -20 to +60
°C (-4 to +140 °F)
Altitude
Operating .................................... 3 km (10 000 feet)
Storage...................................... 12 km (40 000 feet)
Humidity
Operating at 10 to 30
°C (50 to 86 °F).............. 95 %