6.7 Error Messages
The table below shows the error messages which may appear on the display. All error
messages are accompanied by an audio alarm, which you may silence with the [R/B] key.
Message Meaning, Remedy
Hull Unit
HULL UNIT
POWER OFF
(CHECK BREAKER AND FUSE.)
PRESS R/B KEY TO SILENCE ALARM.
Hull unit is not powered. Silence the audio alarm
with the [R/B] key, and then turn on the hull unit
to erase the message and restore normal
operation.
RAISE/LOWER FUNCTION HAS NOT BEEN
COMPLETED.
CHECK IF THE BREAKER AT THE HULL UNIT
HAS BEEN ACTIVATED.
MAXIMUM ALLOWABLE SPEED IS 15 KNOTS
WHILE SOUNDOME IS BEING RETRACTED.
PRESS R/B KEY TO SILENCE ALARM.
You attempted to raise or lower the transducer
when the ship’s speed is above 15 knots or the
breaker on the hull unit tripped. Check the
breaker and lower the ship’s speed below 15
knots to execute function desired.
Frequency Code Error
FREQUENCY CODE ERROR
(CHECK TRANSCEIVER UNIT.)
PRESS R/B KEY TO SILENCE ALARM.
CPU does not receive frequency flag from
transducer. Silence the audio alarm with the
[R/B] key, and then check the transceiver unit.
Train Error
TRAIN NG CPU does not receive heading signal. Check
source of heading signal.
Excessive Speed
SHIPS SPEED EXCEEDS 15 kt.
(SLOW DOWN UNDER 15 kt WHEN MOVING
TRANSDUCER.)
PRESS R/B KEY TO SILENCE ALARM.
TRANSDUCER REMAINS LOWERED.
(REDUCE SHIP'S SPEED AND PRESS
TO
RETRACT IT.)
PRESS R/B KEY TO SILENCE ALARM.
See page 5-11 for details.