Graco 312497G Scuba Diving Equipment User Manual


 
Repair
312497G 15
fitting and slowly operate manual pump to verify
location. If blockage is in this divider valve, go to
step 7.
6. Install manual pump into each indicator port of sec-
ondary divider valve in turn and slowly operate
pump (F
IG. 13). If high pressure exists, blockage
has been located. Look for crushed line, tight
bearing, improperly drilled fittings and/or lube
inlet port. Correct as necessary.
7. Clean Divider Valve
NOTE: Dirt and foreign material will damage lubricating
equipment. Perform all service and disassembly under
the cleanest possible conditions.
a. Before disassembling any divider valve, make a
sketch noting the arrangement of Valve Sec-
tions. For example: INLET 10T - 20S - 10T -
30S - END (F
IG. 14). Also remove end plugs
only and try to move each piston back and forth
without removing the piston from the valve sec-
tion.
b. If all pistons move freely and there is no indica-
tion of a more serious problem, replace end
plugs.
c. Using a new gasket, tighten and torque as indi-
cated in Table 1 (page 11).
FIG. 13
HAND PUMP
SYSTEM PUMP
MASTER
DIVDER
VALVE
SECONDARY
DIVIDER
VALVE
LUBE
OUTLE
T
INDICATOR PORT
PLUGS REMOVED
BEARING
LUBE OUTLETS
FIG. 14
NOTICE
Do not insert hard metal objects into piston bore (i.e.,
punches, screwdrivers, etc.). Hard metal objects can
damage the surface and cause divider valves to leak
fluid. Use a brass rod and hand pressure only.
Inlet
10T
20S
10T
30S
End
Table 4: Torque Values (*see FIG. 1, page 3)
Assembly Torque (ft-lbs)
MJ MD MSP/MH MX MXP MGO
Tie Rod Nuts 12 5-8 23 6-9 12
Indicator Plugs* 6-7 15 8-9 18 12-15 6-8
End Plugs* 11-13 12-15 46 46-50 15
Valve Section
Mounting Screw
--8-9-12-13-