Graco 312964C Marine Sanitation System User Manual


 
Technical Data
312964C 15
Technical Data
NOTE: FCC, C-Tick and IC approvals are for the RF device contained in the Matrix Tank Level Monitor (TLM).
Ultrasonic Tank Depth Measurement range 0 - 30 ft. (0 - 9 m) Not for use in pressurized tanks.
Fluid Level Measurement Accuracy +/- 0.5%
Mounting Standard 2 in. (npt) bung.
Height above tank for TLM and tube mount-
ing
15 in. (30.48 cm).
TLM Mounting Tube and Tank Vent Graco recommends venting the tank separately from the TLM. If not
possible, the TLM mounting and vent function can be combined if
required for tanks with one hole in tank. Be sure TLM is not mounted
close to tank edges or corner.
Weight (with batteries installed) 2.34lb. (1.06 g)
RF Communication 2.4 GHz
Operating Temperature Range -22° F to 185° F (- 30° C to 85° C) Note: Display will not function
below 32°F (0°C).
Storage Temperature Range -40°F to 185°F (-40°C to 85°C)
Batteries Two 9V alkaline
Battery Life 1.5 years
Enclosure IP65
RF Communication 2.4 GHz
Obstructed RF Communication Range
(based on building construction and RF envi-
ronment)
250-300 ft (76.2 - 91.0 m)
Tank Geometry Vertical walled tanks, cylindrical tanks, and obround tanks.
•Vertical Tanks
Maximum Volume 999,999 gallons or liters
Maximum Height 30 ft. (360 in.)
•Cylindrical Tanks
Maximum Volume 999,999 gallons or liters
Maximum Diameter 30 ft. (360 in.)
Maximum Length 30 ft. (360 in.)
•Obround Tanks
Maximum Volume 999,999 gallons or liters
Maximum Height 30 ft. (360 in.)
Maximum Width 30 ft. (360 in.)
Maximum Length 30 ft. (360 in.)
Approvals FCC, Industry Canada (IC), C-Tick, CE