Graco Inc. 308639L Marine Sanitation System User Manual


 
17
17308639
Service
Fig. 8
1
2
3
Cutaway View with Diaphragms in Place Cutaway View with Diaphragms Removed
Lips face out of housing (1).
Side marked AIR SIDE must face center housing (2).
Grease.
Torque to 100 to 120 ft-lb (136 to 163 NSm).
4
06327
06328
52
57
1313
15
1
14
2
1 1
14
14
52
57
303
5
3
3
3
4
4
1
1
301
2
62
62
63
64
63
63
64
06329A
2
Used only in models with PTFE diaphragms.
5
301
302
5
6
6
Bolt–through PTFE diaphragms: Line up diaphragm tabs with tabs on air cover. Bolts go through the diaphragm.