Leica MX535 Marine RADAR User Manual


 
MX535 UAIS Transponder Unit
Technical & Installation Manual
____________________________________________________________________________________________
www.mx-marine.com
29
MX535 PORT CONNECTIONS
M
X420/AIS or MKD
Cable B (NMEA 5)
NMEA5 IN (A)
8
9
10
11
NMEA5 IN (B)
NMEA5 OUT (A
)
NMEA5 OUT (B
)
CHAN
NEL 4
OUT -8
7
6
5
OUT
+
IN -
IN +
MX535 TR
A
NSPONDER
Cable C
(NMEA 8)
16
17
NME
A8 OUT (A)
N
MEA8 OUT (B)
2
1
IN -
IN +
CHANNEL 2
Figure 2.5 - Cable connection for the MX535 AIS to MX420/MKD
3. Power up the MKD and the MX535 transponder.
4. Configure the “Transponder Type” to NAUTICAST and the “Static Config Update” to MKD.
5. Activate the” AIS Connected (to Port 5)” to Yes under the AIS Static setup.
6. Using the built-in Input Monitoring tool of the MKD verify if the output of the MX535 transponder as
shown below is being received on PORT 5 of the MKD. Refer to the MX420 Installation and Service
Manual for the special procedure in “Viewing Input Data”.