Leica MX535 Marine RADAR User Manual


 
MX535 UAIS Transponder Unit
Technical & Installation Manual
____________________________________________________________________________________________
www.mx-marine.com
30
!AIVDO,2,2,0,B,00000000000,2*25
!AIVDO,1,1,,,139K6D7037H@L7FBOLDCr39R0000,0*3D
!AIVDO,1,1,,A,139K6D7037H@L7FBOLDCr39R08AM,0*78
!AIVDO,1,1,,,139K6D7037H@L9:BOLBCr39T0000,0*4F
$AITXT,1,1,31,AIS: Heading valid*0D
$AITXT,1,1,34,AIS: Other ROT source in use*62
!AIVDO,1,1,,,139K6D7037H@L;DBOL=kr39V0000,0*66
!AIVDM,1,1,,B,1000O@B038H@L:vBOL>Cr39V08Bg,0*65
!AIVDO,1,1,,,139K6D7037H@L=FBOL;kr39`0000,0*52
!AIVDO,1,1,,,139K6D7037H@L?LBOL9kr39b0000,0*5A
!AIVDO,1,1,,B,139K6D7037H@L?LBOL9kr39b0D01,0*6D
!AIVDO,1,1,,,139K6D7037H@LALBOL7Sr39d0000,0*14
!AIVDO,1,1,,,139K6D7037H@LC<BOL5Sr39f0000,0*66
!AIVDO,1,1,,,139K6D7038H@LEFBOL3Cr39h0000,0*0D
!AIVDO,1,1,,,139K6D7038H@LGLBOKvkr39j0000,0*6D
!AIVDM,1,1,,A,1000O@B038H@LE2BOL3kr39h0HF7,0*62
!AIVDO,1,1,,,139K6D7038H@LIRBOKtkr39l0000,0*79
!AIVDO,1,1,,,139K6D7038H@LK`BOKrkr39n0000,0*4D
!AIVDO,1,1,,,1000O@OP000`VR4NGvG@0?vF0000,0*53
$AIALR,122514.85,025,A,V,AIS: external EPFS lost*21
$AIALR,122514.85,032,A,V,AIS: Heading lost/invalid*0C
$AITXT,1,1,25,AIS: internal GNSS in use*5C
$AITXT,1,1,28,AIS: internal SOG/COG in use*67
!AIVDO,1,1,,,1000O@OP000`VR4NGvG@0?vH0000,0*5D
$AIALR,122515.86,035,A,V,AIS: no valid ROT information*49
!AIVDO,1,1,,,1000O@OP000`VR4NGvG@0?vJ0000,0*5F
!AIVDO,1,1,,,1000O@OP000`VR4NGvG@0?vV0000,0*43
$AIALR,122522.93,001,A,V,AIS: Tx malfunction*52
Status messages of the connected
sensors, sent when requested
Position report
A
nother message
received
A
larm: External
position data
not available
A
larm: Heading
data not avail
able
A
larm: VHF
transmission
does not work
Figure 2.6 - Protocol AIS TxD
Figure 2.6 - Protocol AIS TxD shows the protocol, which has been transmitted by AIS. The alarm
messages can be forced by disconnecting the sensors and/or the VHF antenna.
If there is no communication on the interface, the AIS is not working. If the power supply and the cable
connection are correct, the AIS Transponder Unit may be defective.
NOTE:
If a ship’s sensor is connected to the interface which has been used for the test, it must be made sure,
that all modifications of the parameterisation of this interface that were necessary for the test are
cancelled.