IS: No valid SOG
information
No data from
external sensor
and from internal
position sensor
Reaction:
The Transponder Unit continues operation.
Remedy:
The telegrams VBW, VTG, RMC can not be received.
Check the sensor and the cabling; Check if the system
that transmits the data is working; Check the baud rate
settings of the sensor inputs.
030
A
IS: No valid COG
information
No data from
external sensor
and from internal
position sensor
Reaction:
The Transponder Unit continues operation.
Remedy:
The telegrams VTG, RMC can not be received. Check
the sensor and the cabling; Check if the system that
transmits the data is working; Check the baud rate
settings of the sensor inputs.
032
A
IS: Heading lost/invalid
No data from
external sensor
Reaction:
The Transponder Unit continues operation.
Remedy:
The telegrams HDT can not be received. Check the
sensor and the cabling; Check if the system that
transmits the data is; Check the baud rate settings of
the sensor inputs.
035
A
IS: No valid ROT
information
No data from
external sensor
Reaction:
The Transponder Unit continues operation.
Remedy:
The telegrams ROT can not be received. Check the
sensor and the cabling; Check if the system that
transmits the data is; Check the baud rate settings of
the sensor inputs.
051
A
IS: Channel management
information not accepted
E.g. overlapping
with an existing
area
Reaction:
The Transponder Unit continues operation.
Remedy:
Check the channel management information.
052
A
IS: GPS receiver fault
Reaction:
The Transponder Unit continues operation without
internal GPS data and without direct GPS time
synchronization.
Remedy:
The Transponder Unit must be exchanged.
0204
A
IS: offline
No connection
between CDU and
Transponder Unit
Reaction:
The Transponder Unit continues operation.
Remedy:
The cabling must be checked.