MicroNet Technology MN100 Marine Instruments User Manual


 
mn100 Dual Digital Display
16
(p32) Target Page
Produces a “Trim” indication showing an increase or decrease
in value from a set point. First select the appropriate chapter
in the upper display using the button then select “Lock” in
the lower display using the or buttons. Pressing the button
will lock the upper display value and the lower display will
now indicate increase or decrease from the set value. Values
displayed as units will show a percentage (%) increase or
decrease whereas values displayed as degrees will show the
difference in degrees.
Heading locked at 269
0
now
showing +008 change meaning
current heading is 277
0
Speed locked at 8.69 kts now
showing +10% change meaning
current speed is 9.56 kts)
Setup and Calibration
21
(s9) LOG UNITS
The units in which ALL distance related information is
displayed. Nautical Miles (NM), Kilometres (KM) or Statute
Miles (SM).
(s10) TEMP UNITS
The units in which the Sea Temperature reading is displayed.
Degrees Celsius (
0
C) or Degrees Fahrenheit (
0
F).
3.4.3 Alarms Chapter
In each case press the button quickly to edit, press the or
to change values and press the button quickly to save the
entered value. In the case of On/Off selection the
button will
toggle the setting On and Off. Default values are indicated in bold.
(s11) DEPTH SHALL
Sets the Shallow Depth at which the instrument will alarm.
OFF and 0 to 7.6m (0 to 25 ft.) (0 to 4 ftms). Values are
displayed in the previously selected units (see page 18 -s7)
and are all subject to any keel or waterline offset added (see
page 20 -s21). This alarm sounds as the depth passes below
the set value and NOT as the depth increases past this
value.
(s12) DEPTH DEEP
Sets the Deep Depth at which the instrument will alarm. OFF
and 0 to 76.2m (0 to 250 ft.) (0 to 41.6 ftms). Values are
displayed in the selected units (see page 18 -s7) and are all
subject to any keel or waterline offset added (see page 23).
This alarm sounds as the depth increases past this value or
decreases past this value.
(s13) OFF CRSE
Sounds if the vessel moves further than the set distance
away from a “Locked” heading (see page 19 -s12). Off/On
(s14) WIND HIGH
Sets the Wind Speed at which the instrument will alarm. OFF
and 0.0 to 100 knots (0.0 to 51.4 m/s). Values are displayed
in the previously selected units (see page 18 -s8). This alarm
sounds as the wind speed increases past the set value and
NOT as it decreases past this value.