PAGE 28 —GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV. #1 (02/25/14)
MAINTENANCE
Table 3. Troubleshooting
SYMPTOM POSSIBLE PROBLEM SOLUTION
Lamp does not light.
Is plug disconnected? Plug in correctly.
Is generator power switched off? Turn on switch.
Is lamp loose? Screw lamp securely into socket.
Is power connector disconnected or
loose?
Connect disconnected connector.
Is model of lamp incompatible? Use genuine MQ lamp.
Lamp only lights for a short time.
Is ambient temperature too high -
more than 104° F (40° C)?
Move lamp where there is proper
ventilation.
Balloon does not inflate.
Is fan motor not working properly? Check and repair fan motor.
Is balloon cloth defective? Repair or replace balloon cloth.
Is Lamp 1 on but fan is not working? Check and repair fan motor.
Only Fan is working. Is Lamp 1 not turning on? Check Lamps and cable wiring.
Shuts down after 30 seconds. Is Microswitch being pressed? Check Microswitch or repair fan motor.
LAMP
MICRO SWITCH
LAMP
Figure 24. Location of Maintenance Parts