Oceanic 04.8367.72 Scuba Diving Equipment User Manual


 
21
ATOM 3.0 OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5216-r02 (9/6/11)
Set End Alarm (TMT 1, 2, 3) information includes (Fig. 56):
> Graphics SEt and END AL with all Tank icons (1, 2, 3).
> Set Point graphic OFF (or Pressure value) flashing, with PSI (or BAR) icon.
• A (hold) - to scroll upward through Set Points (8/sec) from 300 to 1500 PSI (20 to 105 BAR) in 100 PSI (5 BAR) increments.
• A (< 2 sec) - to step upward through Set Points.
• M (< 2 sec) - to step back through Set Points.
• S (< 2 sec) - to save the setting and access Set PO2 Alarm.
• S (2 sec), if no change - to revert to Set Turn Alarm.
Set PO2 Alarm (NORM), information includes (Fig. 57):
> Graphic SEt and AL.
> PO2 value (ATA) flashing with icon.
• A (< 2 sec) - to step upward through Set Points from 1.20 to 1.60.
• M (< 2 sec) - to step back through Set Points.
• S (< 2 sec) - to save the setting and revert to Set A Lead-in.
• S (2 sec), if no change - to revert to Set End Alarm.
SET U GROUP (UTILITIES)
Selections >> Wet > Units > DS* > SS* > Algo* > CF* > Glo > SR > TMT 1 > TMT 2 > TMT 3.
*Items apply to NORM only.
> Set Points remain as set until changed.
Set U Lead-in, information includes (Fig. 58):
> Graphics Goto and SET U.
• A (< 2 sec) - to step forward to Select DIVE OP mode.
• M (< 2 sec) - to step back to SET A.
• S (< 2 sec) - to access Set Wet.
Set Wet Activation, information includes (Fig. 59):
> Graphics SEt and WET.
> Set Point graphic ON (or OFF) flashing.
• A or M (< 2 sec) - to toggle between ON and OFF.
• S (< 2 sec) - to save the setting and access Set Units.
• S (2 sec), if no change - to revert to SET U.
Set Units, information includes (Fig. 60):
> Graphic SEt and UNIT.
> Set Point icons FT and PSI (or M and BAR) flashing.
• A or M (< 2 sec) - to toggle between FT/PSI and M/BAR.
• S (< 2 sec) - to save the setting and access Set DS if NORM, or Set Glo if GAUG.
• S (2 sec), if no change - to revert to Set Wet.
Set DS (NORM Deep Stop), information includes (Fig. 61):
> Graphic SEt and DEEP St with Stop arrow/bar icons.
> Set Point graphic ON (or OFF) flashing.
• A or M (< 2 sec) - to toggle between ON and OFF.
• S (< 2 sec) - to save the setting and access Set SS.
• S (2 sec), if no change - to revert to Set Units.
When set On, the Deep Stop feature activates when descent is made to a depth deeper than 80 FT (24 M) during No Deco.
A Stop Depth is calculated to be 1/2 the Max Depth achieved, then upon ascent to within 10 FT (3 M) below that depth, the Deep Stop screen is
displayed in place of the No Deco Main.
Fig. 56 - SET END AL
(applies to TMT in use)
Fig. 57 - SET PO2 AL
Fig. 58 - SET U LEAD-IN
Fig. 59 - SET WET
ACTIVATION
Fig. 60 - SET UNITS
Fig. 61 - SET DS