Oceanic 04.8367.72 Scuba Diving Equipment User Manual


 
52
ATOM 3.0 OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5216-r02 (9/6/11)
CAN BE USED AS
Watch
Dive Computer (Air or Nitrox) with up to 3 Gases up to 100% O2 and 3 Transmitters.
Digital Depth Gauge/Timer with up to 3 Transmitters.
Free Dive (breath hold) activity with Depth Gauge/Countdown Timer.
DIVE COMPUTER PERFORMANCE
Buhlmann ZHL-16c based PZ+, or DSAT based, algorithm.
No Deco limits closely follow PADI RDP.
Decompression in agreement with Buhlmann ZHL-16c and French MN90.
No Deco Deep Stops >> Morroni, Bennett.
Deco Deep Stops (not recommended) >> Blatteau, Gerth, Gutvik.
Altitude >> Buhlmann, IANTD, RDP (Cross).
Altitude corrections and O2 limits based on NOAA tables.
TRANSMITTERS
Battery and Pressure check
> every 2 minutes when asleep
> every 2 seconds when awake
Startup
> Pressure => 120 PSI (8 BAR)
> Battery => 2.75 volts
Shutdown
> Pressure < 50 PSI (3.5 BAR)
TMT Compatibility with Nitrox
When packaged and shipped from the factory, Oceanic TMTs are rated for use with compressed Air and Nitrox mixtures containing up to 99% O2 by volume and with 100% O2.
OPERATIONAL PERFORMANCE
Function: Accuracy:
Depth ±1% of full scale
Timers 1 second per day
Dive Mode Activation:
• Must be in Dive Computer mode, if Wet Activation is set OFF.
• Automatic by immersion in water, if Wet Activation is set ON.
• Cannot be manually activated deeper than 4 FT (1.2 M), if Wet Activation is set OFF.
• Cannot operate as a DC at elevations higher than 14,000 feet (4,270 meters).
Dive Counter:
NORM/GAUG displays Dives #1 to 24, FREE displays #1 to 99 (0 if no dive made yet).
Resets to Dive #1, upon diving (after 24 hours with no dives).
Dive Log Mode:
Stores 24 most recent NORM/GAUG dives in memory for viewing.
After 24 dives, adds 25th dive in memory and deletes the older dive.
Altitude:
Operational from sea level to 14,000 feet (4,270 meters) elevation.
Measures ambient pressure every 30 minutes in Watch mode, when Dive Computer mode is accessed, and every 15 minutes while in DC Surface modes.
Does not measure ambient pressure when Wet.
Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.
Power:
• Watch Battery (1) 3 vdc, CR2450, Lithium battery (Panasonic or equivalent)
• Transmitter Battery (1) 3 vdc, CR2, .75 Ahr, Lithium battery (Duracell model DL-CR2 or equivalent)
• Shelf life Up to 7 years (when shipped from factory in Deep Sleep mode)
• Replacement User replaceable (annual recommended)
• Use Life (ATOM 3.0) 1 year or 300 dive hours if (2) 1 hour dives per dive day
• Use Life (Transmitter) 300 dive hours if (2) 1 hour dives per dive day
Battery Indicator (ATOM 3.0 only):
Warning >> icon on solid when <= 2.75 volts, Battery change recommended.
Alarm >> icon on ashing when <= 2.50 volts, change the Battery, will not function as a DC.
Operating Temperature:
Out of the water >> between 20 °F and 140 °F (-6 and 60 °C).
In the water >> between 28 °F and 95 °F (-2 and 35 °C).
BAR GRAPHS:
TLBG segments
• No Deco Normal zone 1 to 3
• No Deco Caution zone 4
• Decompression zone 5 (all)
VARI 60 FT (18 M) & Shallower Deeper than 60 FT (18 M)
segments FPM MPM segments FPM MPM
0 0 - 10 0 - 3 0 0 - 20 0 - 6
Normal zone 1 11 - 15 3.5 - 4.5 1 21 - 30 6.5 - 9
Normal zone 2 16 - 20 5 - 6 2 31 - 40 9.5 - 12
Normal zone 3 21 - 25 6.5 - 7.5 3 41 - 50 12.5 - 15
Caution zone 4 26 - 30 8 - 9 4 51 - 60 15.5 - 18
Too Fast zone (ashing) 5 (all) > 30 > 9 5 (all) > 60 > 18
SPECIFICATIONS