Outback Power Systems GFX1448E Marine Battery User Manual


 
Specifications
52 900-0112-01-00 Rev B
Table 22 48-Volt Inverter Settings (MATE3)
Field Item Default Minimum Maximum
Sensitivity (see page 14 for increments)
6 0 50
Pulse Length
8 4 20
Search
Pulse Spacing
60 AC cycles 4 AC cycles 120 AC cycles
Input Type Grid Grid or Gen
Input Support Y Y or N
Grid Input AC Limit
25 Aac 2.5 Aac 30 Aac
Gen Input AC Limit
25 Aac 2.5 Aac 30 Aac
AC Input and
Current Limit
Charger AC Limit
5.5 Aac 0 Aac 6 Aac
AC1/Grid Lower Limit
208 Vac 140 Vac 220 Vac
AC1/Grid Upper Limit
252 Vac 250 Vac 280 Vac
Grid AC Input
Voltage Limits
AC1/Grid Transfer Delay
6 AC cycles 0 AC cycles 240 AC cycles
LowerVoltage Limit
208 Vac 140 Vac 220 Vac
Upper Voltage Limit
252 Vac 250 Vac 280 Vac
Transfer Delay
60 AC cycles 0 AC cycles 240 AC cycles
Gen AC Input
Voltage Limits
Connect Delay
0.5 minutes 0.2 minutes 15 minutes
AC Output
AC Output
230 Vac 210 Vac 250 Vac
Cut-Out Voltage
42 Vdc 36 Vdc 48 Vdc
Low Battery
Cut-In Voltage
50 Vdc 40 Vdc 56 Vdc
Absorb Voltage
57.6 Vdc 52 Vdc 64 Vdc
(Absorb) Time
1.0 hours 0.0 hours 24.0 hours
Float Voltage
54.4 Vdc 48 Vdc 60 Vdc
(Float) Time
1.0 hours 0.0 hours 24.0 hours
Battery Charger
Re-Float Voltage
50 Vdc 48 Vdc 26 Vdc
Equalize Voltage
58.4 Vdc 56 Vdc 68 Vdc
Battery Equalize
(Equalize) Time
1.0 hours 0.0 hours 24.0 hours
Aux Mode Cool Fan
Remote, Load Shed, Gen Alert, Fault, Vent Fan,
Cool Fan, Divert DC, Divert AC, or AC Drop
(Load Shed) Enable Voltage
44 Vdc 40 Vdc 56 Vdc
(Gen Alert) ON Voltage
44 Vdc 40 Vdc 56 Vdc
(Gen Alert ON) Delay
4 minutes 0 minutes 240 minutes
(Gen Alert) OFF Voltage
56 Vdc 48 Vdc 72 Vdc
(Gen Alert OFF) Delay
9 minutes 0 minutes 240 minutes
(Vent Fan) Enable Voltage
52 Vdc 40 Vdc 64 Vdc
(Vent Fan) Off Period
5 minutes 0 minutes 30 minutes
(Divert DC or AC) Enable Voltage
58.4 Vdc 48 Vdc 64 Vdc
Auxiliary
Output
(Divert DC or AC) Off Delay
30 seconds 0 seconds 240 seconds
Inverter
Stacking
Stack Mode Master Master, OB Slave L1, 3p Classic B , 3p Classic C
Master Adjust Only
0 0 7
Power Save
Slave Adjust Only
1 1 15
Grid Tie Enable Y Y or N
Sell Voltage
47.2 Vdc 40 Vdc 60 Vdc
Grid-Tie Sell
Grid Tie Window IEEE IEEE or user
Input Voltage
11
-1 -3 1
Output Voltage
11
-1 -3 1
Calibrate
Battery Voltage
12
0.0 -0.8 0.8
11
These values represent an adjustable setting with a total range of 4 Vac. The default value of -1 means the calibration will subtract 1 volt from the measured
value. The range of settings allow up to 1 volt to be added to the measured value, or up to 3 volts to be subtracted from it. The result is also displayed.
12
These values represent an adjustable setting with a range of ± 0.8 Vdc from the measured value. The range of settings allow up to 0.8 volts to be either added
or subtracted from the measured value (in increments of 0.4 Vdc). The result is also displayed.