Locate disconnects in an easily accessible location. Operators
should not have to squeeze around the unit to reach disconnects,
especially in case of emergency.
When running conduit whips to the unit, make sure that whips are
routed away from hot piping.
Check the unit nameplate for correct voltage and amperage before making electrical
connections!
! DANGER
Improper electrical connections can
damage the unit and cause serious
operator injury or death!
Make sure that all electrical
connections are made by a qualified
electrician, and that all connections
are tight.
Make all electrical supply connections at the front of the unit. An access panel covers all
electrical connections. Run electrical connections to the supply terminals from either side of
the unit. Make sure that all three phases are wired correctly. The pump runs backwards if not
wired properly.