Sterling 6010 Marine Instruments User Manual


 
Portable Hot Oil Temperature Control Units Page 7
1-4 Standard Features
Off-the-shelf microprocessor-based PID temperature controller
with Process and Set Point LED readouts
6kW low watt density immersion heater with IEC contactors
400°F (204ºC) maximum operating temperature
Branch fusing
System status graphic display
NEMA 1 electrical enclosure
2 gallon (8 liter) expansion tank
To Process pressure gauge
Independent safety thermostat with safety contactor
Pressure actuated bypass
Positive displacement pumps with mechanical seal
Easily removable panels for quick access to internal components
1-5 Available Options
Manual bypass
Y-strainer on From Process line
General fault visual alarm
Omron E5CK controller with:
4-20 mA current control output
RS-232 or RS-485 communications
Remote sensor; 10 ft. (3 m)
Heat exchanger options of 3.9 sq. ft. (0.3627 sq. m)
Audible alarm
Lexan cover
Optional operating voltages of 208/3/60, 230/3/60, 575/3/60,
380/3/50, and 415/3/50
1-6 Feature Descriptions
Immersion Heaters
The fluid is heated by the specially designed three-phase low watt density electrical
immersion heater, and regulated by the controller. The standard heater has a steel sheath for
low watt density and good heat transfer.
This unit is supplied with a 6 kW low watt density immersion heaters.