Toro SA41 Marine Battery User Manual


 
12
AC VOLTS SETTING
ALARM INPUTS
The ENERGY MANAGEMENT
has 2 alarm inputs (shown on pages 25 and 26) which can be set to
trigger an alarm condition. (See page 15).
Use the ‘Lo’ setting if the input is connected to a normally closed set of contacts (see fig 2.1 on page
26), of when the voltage falls below 1V on alarm (see fig. 2.4).
Use the ‘Hi’ setting if the input is connected to a normally open set of contacts (see fig. 2.2 on page 26),
or when the voltage rises above 3V on alarm (see fig. 2.3).
ALARM INPUT 1
ALARM INPUT 2
EXTERNAL KEYPAD
CURRENT SHUNT SETTINGS
EXTERNAL SHUNT
If the current shunt is set to YES the following settings will be displayed.
AC Volts : 240V
[Set Parameters]
Alarm 1 active : Hi
[Set Parameters]
Alarm 2 active : Hi
[Set Parameters]
Ext. Keypad : YES
[Set Parameters]
Ext. Shunt : YES
[Set Parameters]
Allows the output voltage to be set from 220V to 240V if an output voltage
other than 240V is required. Use the UP or DOWN keys to set the value.
NZ users should set this to 220VAC.
Set alarm input 1 to HI or LO active. Use the UP or DOWN keys to change
the setting.
Set alarm input 2 to HI or LO active.
This is set to YES if an optional external keypad (SA-KP-01) is connected.
Otherwise this is set to NO. See page 27. Use the UP or DOWN keys to
change the setting.
This is set to YES if an optional external current shunt (SA-S200) is
connected. Otherwise this is set to NO. See page 28. Use the UP or DOWN
keys to change the setting.